1-1/4 (32 mm) steel corner bead crimp-attached at 6 (152 mm) intervals. and 18-gauge (43 mils) wire tied 24 (610 mm) o.c. Fiberglass Insulation. ULC W301 allows vertical application only. The intuitive search tool allows you to quickly locate the product or component that will meet your needs. Click below for details. USG STRUCTO-CRETE Brand Structural Panels. Interior: Two layers 5/8 (15.9 mm) DensArmor Plus Fireguard or 5/8 (15.9 mm) ToughRock Fireguard X applied horizontally or vertically to framing. Face Layer: 5/8 (15.9 mm) ToughRock Fireguard C gypsum board applied or 5/8 (15.9 mm) DensArmor Plus Fireguard C (UL L505 only) applied perpendicular to resilient channels with 1 (25 mm) Type S screws 12 (305 mm) o.c. Joint compound 1/16 (2.0 mm) thick applied over corner bead. Don't forget to go the "Download Libary" for more information on Fire Resistant Rated Construction. 1/2 (12.7 mm) ToughRock Fireguard C or 1/2 (12.7 mm) DensArmor Plus Fireguard C gypsum panels applied perpendicular to resilient channels 24 (610 mm) o.c. Firestop systems. Bracing: Lateral bracing spaced not over 40 (1,016 mm) o.c. Furring channels attached with 18-gauge (43 mils) wire ties to open web steel joists 24 (610 mm) o.c. 3/4 (19 mm) air space on both sides must be maintained between liner panels and adjacent framing. Non-Load Bearing, 5/8 (15.9 mm) ToughRock Fireguard X or 5/8 (15.9 mm) DensArmor Plus Fireguard gypsum panels applied vertically to each side of 3-5/8 (92 mm) steel studs 24 (610 mm) o.c. and to base layer with 1-1/2 (38 mm) Type G drywall screws 12 (305 mm) o.c. Any products manufactured by persons other than Georgia-Pacific Gypsum are presented for illustration only. 1/2" (12.7 mm) ToughRock Fireguard 45 gypsum board applied vertically or horizontally to each side of 2 x 4 wood studs 24 (610 mm) o.c. thick structural sheathing (plywood) complying with DOC PS1 or PS2, or APA Standard PRP-108, manufactured with exterior glue, may be applied horizontally or vertically to the . Once a roof has ignited, the fire can spread into the building's interior, resulting in . Studs located at each corner of heavy steel W14 x 233 (metric W360 x 347) column. Horizontal joints on opposite sides need not be staggered. with 1 (25 mm) Type S drywall screws 24 (610 mm) o.c. at edges and ends and 8 (203 mm) o.c. Or search by the assembly number (UL design, or Gypsum Association . UL FIRE RATED ASSEMBLIES UL Fire Resistance Ratings (continued) Restrained Assembly Ratings (hr.) Second Layer: Attached with 1-5/8 (41 mm) Type S drywall screws 24 (610 mm) o.c. 704 is the prescriptive portion of the IBC - chapter 7.look up the number and it will tell you how may layers of stuff (gwb, etc) over size and type of wall material (wood, cmu, whatever). Please visit www.buildgp.com/safetyinfo for additional information. Certified materials are added to the UL iQ databases on a daily basis, making this information immediately available to thousands of . Watch this video to learn how you can quickly access UL certification and guide information. Cement stucco applied over wire mesh in two 1/2 (12.7 mm) thick coats with bonding agent applied between coats. Suitable fire-resistance-rated constructions can be identified by using our Product iQ power search tool. Our Standards Catalog provides a listing of UL Standards and ULC Standards. Architecture, Engineering and Construction, Information and Communications Technology, Residential and Commercial Air Conditioning, Lighting Safety Testing and Certification, Enhance sustainability throughout properties, Computer and Hardware Performance Benchmarking, Benchmark Automation Platform for Enterprises, ESG and Sustainability Management Software, Sustainability and ESG Reporting for Enterprise, GxP Training and Qualification for Life Sciences, Occupational Health for Clinics and Hospitals, Product Design, Compliance and Regulatory Insights, Regulatory Compliance Software for Life Sciences, Security and Compliance for Connected Devices, Wire and Cable Design and Manufacturing Software, Microgrids, Distributed Energy Resources & Hybrid Projects, Materials Data Collection and Management, Fire Resistance Products, Systems and Designs, EU CE Marking Technical Documentation File Service, Brazil INMETRO Mark Certification Services, Materials & Equipment Acceptance (MEA) Report, Engineering Evaluation & Support Services, UL 263/ASTM E119 & BS476 Fire Resistance Rating. Horizontal joints need not be backed by framing. Ethics & Compliance. Stagger joints 16 (406 mm) o.c. at edges and ends and 12 (305 mm) o.c. 1/2 (12.7 mm) ToughRock Fireguard C or 1/2 (12.7 mm) DensArmor Plus Fireguard C gypsum panels applied perpendicular to resilient channels 24 o.c. How to use the UL Certifications Directory to Search for fire rated Wall, Floor, Roof, and Structural Assemblies Online Face layer vertical joints offset one stud cavity from base layer vertical joints. Opposite side: Base layer of 5/8" (15.9 mm) ToughRock Fireguard X Products or 2/8" (15.9 mm) DensArmor Plus Fireguard gypsum panels installed horizontally or vertically with 1" Type S screws 24" o.c. Face Layer: 5/8 (15.9 mm) ToughRock Fireguard C gypsum board or 5/8 (15.9 mm) DensArmor Plus Fireguard C gypsum panels applied perpendicular to channels with 1-5/8 (41 mm) Type S drywall screws, 8 (203 mm) o.c. Furring channels wire tied to open web steel joists 24 (610 mm) o.c supporting 3/8 (10 mm) rib steel lath or 9/16 (14 mm) deep 28-gauge (15 mils) corrugated steel and 2 (51 mm) concrete slab measured from top of flute. in field. Joint systems. Similar to the Online Certifications Directory (Product iQ), many end-product manufacturers use this database to verify the certification information of the components they intend to use in their end-product applications. 3-1/2 corrosion resistant 25-gauge (18 mils) steel studs 24 (610 mm) o.c. All-new fire-rated floor-ceiling assembly files. Connect with us in person or online, around the globe. Interior Base Layer: 5/8 (15.9 mm) ToughRock Fireguard X Products or 5/8 (15.9 mm) DensArmor Plus Fireguard gypsum panels applied vertically or horizontally to 2x 4 wood studs 16 (406 mm) o.c. Interior: Two layers 5/8 (15.9 mm) DensArmor Plus Fireguard or 5/8 (15.9 mm) ToughRock Fireguard X applied vertically to framing. Gypsum panels end joints located over continuous channels and attached to additional pieces of channel 54 (1372 mm) long located midway between continuous channels at end joints. UL Design No. Type C gypsum board will maintain its material integrity in a fire condition better than Type X gypsum board. 2 (51 mm) maximum foam-on-plastic thickness. Selecting the Right UL Fire-Rated Assembly 1. 4B. to intermediate studs. Delve into detailed press kits for information on our work. Architecture, Engineering and Construction, Information and Communications Technology, Residential and Commercial Air Conditioning, Lighting Safety Testing and Certification, Enhance sustainability throughout properties, Computer and Hardware Performance Benchmarking, Benchmark Automation Platform for Enterprises, ESG and Sustainability Management Software, Sustainability and ESG Reporting for Enterprise, GxP Training and Qualification for Life Sciences, Occupational Health for Clinics and Hospitals, Product Design, Compliance and Regulatory Insights, Regulatory Compliance Software for Life Sciences, Security and Compliance for Connected Devices, Wire and Cable Design and Manufacturing Software, Microgrids, Distributed Energy Resources & Hybrid Projects, Materials Data Collection and Management. Joints staggered. Drywall end joints located midway between continuous channels and attached to additional pieces of channel 52 (1321 mm) long with screws 8 (203 mm) o.c. xks{fD4Lt6M|mg@KF. Joints staggered. OK, there are also interior one-hour rated walls, but in this case, the brick veneer tells me its probably exterior. Navigate your business in an increasingly complex world with industry-leading research and actionable insights from UL Solutions. Vertical joints in adjacent layers staggered one stud cavity. (NLB). Sound Tested with 3-1/2 (89 mm) fiberglass insulation friction fit in stud space, 5/8 (15.9 mm) ToughRock Fireguard X or 5/8 (15.9 mm) DensArmor Plus Fireguard gypsum panels applied vertically to a double row of 1-5/8 (41 mm) (15 mils) steel studs 24 (610 mm) o.c. This powerful online search tool that can help you easily locate the UL Solutions certification information needed to achieve safe, sustainable code complaint installations. Only products which bear UL's Mark are considered Certified. 5/8 (15.9 mm) ToughRock Fireguard X or 5/8 (15.9 mm) DensArmor Plus Fireguard gypsum panels applied vertically (or horizontally to each side of double row of 2 x 4 wood studs 16 (406 mm) o.c. Joints staggered 24 (610 mm) each layer and side. Access UL certification data on products, components and systems, identify alternatives and view guide information with Product iQ. with 1 (25 mm) Type S drywall screws 24 (610 mm) o.c. Ability to provide thermal resistance for comfort and efficiency. Our solutions also help confirm the safety, performance, reliability and security of your fire-resistant rated designs. Fiberglass insulation, 2-3/4" (70 ,,) thick, 0.30 pcf (4.8 kg/m3), friction fit in stud space. at vertical joints and 36 (914 mm) o.c. The listed assemblies contained in the guide are grouped generically based on deck classification. to open web steel joists supporting 3/8 (10 mm) rib steel lath or 9/16 (14 mm) deep 28-gauge (15 mils) corrugated steel and 2-1/2 (64 mm) concrete slab measured from top of flute. 2. Resilient channels attached 16 (406 mm) o.c. All-new fire-rated roof-ceiling assembly files. V340 (1-hour from either side) UL Design No. Face Layer: 5/8 (15.9 mm) ToughRock Fireguard X Products or 5/8 (15.9 mm) DensArmor Plus Fireguard gypsum panels applied perpendicular to resilient channels through base layer with 1-7/8 (48 mm) Type S screws 8" o.c. Sound tested with 2-1/2 (64 mm) fiberglass insulation. Stagger joints each side. and with 1-1/2 (38 mm) Type G drywall screws 24 (610 mm) o.c. This intuitive search tool allows you to quickly locate the product or component that will meet your needs. However, evaluation by comparison of tested assemblies is permitted by IBC Section 703.3, item 4. One layer 5/8 (15.9 mm) ToughRock Fireguard C gypsum board or 5/8 (15.9 mm) DensArmor Plus Fireguard C gypsum panels applied at right angles to resilient or rigid furring channels with 1 (25.4 mm) Type S drywall screws 12 (305 mm) o.c. with 6d common nails. Architecture, Engineering and Construction, Information and Communications Technology, Residential and Commercial Air Conditioning, Lighting Safety Testing and Certification, Enhance sustainability throughout properties, Computer and Hardware Performance Benchmarking, Benchmark Automation Platform for Enterprises, ESG and Sustainability Management Software, Sustainability and ESG Reporting for Enterprise, GxP Training and Qualification for Life Sciences, Occupational Health for Clinics and Hospitals, Product Design, Compliance and Regulatory Insights, Regulatory Compliance Software for Life Sciences, Security and Compliance for Connected Devices, Wire and Cable Design and Manufacturing Software, Microgrids, Distributed Energy Resources & Hybrid Projects, Materials Data Collection and Management, Product Sourcing and Certifications Database, Access printable UL certification letters, Save regularly used, custom and complex queries, Leverage custom tagging and grouping of content, Receive automatic notification of updates to a search or file. We'll send you a link that lets you create a new password. D798 Unres NWC All. Base Layer: 1/2 (12.7 mm) ToughRock Fireguard C gypsum board or 1/2 (12.7 mm) DensArmor Plus Fireguard C gypsum panels applied vertically to each side of 1-5/8 (41 mm) metal studs 24 (610 mm) o.c. supporting 3/8 (10 mm) rib steel lath and 2 (51 mm) concrete slab. Explore our business intelligence-building digital tools and databases, search for help, review our business information, or share your concerns and questions. Face Layer: 5/8 (15.9 mm) ToughRock Fireguard X Products or 5/8 (15.9 mm) DensArmor Plus Fireguard applied perpendicular to joists with 1-7/8 (48 mm) Type S-12 drywall screws 12 (305 mm) o.c. See photos of 100s of finished projects from across the globe. Step-by-step instructions on locating rated walls, floors, beams and columns. Find Your Architectural Rep. Gypsum Board* (As an alternate to Item 4) 5/8 in. Optional (15 mils), stud or runner pieces not less than 4-1/2 (114 mm) long may be used as cross braces and attached with two No. Joints staggered 24" on Opposite Sides. Face Layer: 5/8 (15.9 mm) ToughRock Fireguard X or 5/8 (15.9 mm) DensArmor Plus Fireguard gypsum panels applied horizontally to studs with 2-1/2" Type W Screws 8 (203 mm) o.c. UL D798. Wood joists supporting 1 (25 mm) nominal T&G wood sub and 1 (25 mm) nominal finish floor, or 19/32 (15.1 mm) plywood finished floor with long edges T&G and 15/32 (11.9 mm) interior plywood with exterior glue subfloor perpendicular to joists with joints staggered. ULC Standards develops and publishes standards and specifications for products having a bearing on fire, life safety and security, crime prevention, energy efficiency, environmental safety, security of assets and facilities, live working and workplace safety and other areas. Plywood end joints staggered 48 (1219 mm). each layer and side. One layer of 1" x 24" DensGlass Shaftliner or ToughRock Shaftliner inserted between 2-1/2" floor and ceiling runners of minimum 2-1/2" C-T, C-H or I studs between panels. Please enter the email address you used to create the account. I have spoke with UL and IBC. GP Gypsum disclaims any responsibility or liability for the use of this information and for the architecture, design, engineering or workmanship of any project, assembly or system. 5/8 (15.9 mm) gypsum board pieces 12 (305 mm) long x 4-1/2 (114 mm) wide located at 1/3 points used as cross braces fastened to stud pairs with three 1 (25 mm) Type S drywall screws at each end of brace. Some of our systems also have T and L Ratings. 20-gauge (33 mils) hexagonal steel mesh fitted between middle and face layers of gypsum board along bottom and extending 1-1/2 (38 mm) onto sides. ^}2R*?gLH d=vnW*x{Y_-
ir|>vqx_^/}T!FdcQ,[ )b.TH%5P;>/|}Cv D]f"u&""NXBRuuJDr?P`$EbXxEQ2x8Xzae3(_%O^qp)se$u#"`K#ki=;Ae'DnZSE2G~ Upper channels secured to steel deck units with 1/2 (12.7 mm) Type S pan-head screws spaced 12 (305 mm) o.c. Fire-resistance rated designs are used to achieve code compliant installations where the building codes require hourly rated designs. (NLB). and 1-1/2 (38 mm) Type G drywall screws midway between studs 1-1/2 (38 mm) above and below horizontal joints. The Only Wallboard Specifiable for Sustainability. This next-generation search engine covers a wide range of construction materials, equipment and fire-resistance rated assemblies and systems. endobj
Please enter the email address you used to create the account. endobj
02-18-2007, 07:16 PM. Vertical joints centered over studs and staggered one stud cavity on opposite sides of studs. Horizontal joints on opposite sides need not be staggered. Interior: Base layer 5/8 (15.9 mm) DensArmor Plus Fireguard or 5/8 (15.9 mm) ToughRock Fireguard X Products applied vertically to studs with 6d coated nails, 1-7/8 (48 mm) long, 0.0915 (2 mm) shank, 1/4 (6 mm) heads, 12 (305 mm) o.c. Fire Resistance Ratings - ANSI/UL 263 See General Information for Fire Resistance Ratings - ANSI/UL 263 Design No. Outer Layer: Gypsum board attached to the sheet metal angles with 1-5/8 (41 mm) long selfdrilling, self-tapping screws spaced vertically 12 (305 mm) o.c. Edges and ends offset 24" (610 mm) o.c. If a construction element is identified as "optional" or "may be provided" it is not mandatory and doesn't need to be included in the construction. Joints staggered 24 (610 mm) each layer and side. Access UL certification data on products, components and systems, identify alternatives and view guide information with Product iQ. Frank C. Morris, CBO, CEAP, MCP. Determine the existing or planned building elements, including structural, mechanical, Joint compound 1/16 (1.6 mm) thick applied over corner bead and entire outer layer of drywall. End joints secured to both resilient channels. Face Layer: 5/8 (15.9 mm) ToughRock Fireguard X Products or 5/8 (15.9 mm) DensArmor Plus Fireguard gypsum panels applied perpendicular to joists through base layer with 1-7/8 (48 mm) Type W or S screws 12 (305 mm) o.c. when applied horizontally to framing. Sound tested with studs 16 (406 mm) o.c. Face Layer: 1/2 (12.7 mm) ToughRock Fireguard C or 1/2 (12.7 mm) DensArmor Plus Fireguard C gypsum board applied vertically to each side with 1-5/8 (41 mm) Type S drywall screws 12 (305 mm) o.c. at joints and intermediate joists. You are leaving the UL Solutions website for an external site. Search the catalog for the Standards you need and then purchase them on our Standards sales site. <>
CREATE A SUBMITTAL. Dedicated to exploring vital questions related to public . <>
Unrestrained Assembly Ratings (hr.) About 3M. We have tested products for public safety for 100 years and we are accredited by the Standards Council of Canada. suspended from the upper channels with 1/2 (12.7 mm) Type S pan-head screws and supported steel channels installed at lower corners of brackets. with 1 (25 mm) Type S drywall screws 24 (610 mm) o.c. 5/8 (15.9 mm) ToughRock Fireguard X or 5/8 (15.9 mm) DensArmor Plus Fireguard gypsum panels applied vertically (per ULC W301) or horizontally (UL U305) to each side of 2 x 4 wood studs 16 (406 mm) o.c. If a dimension is indicated as a minimum or maximum, the construction can include greater or lesser dimensions, respectfully. Estimate materials and find USG equivalents for your building projects. Resilient channels applied perpendicular to bottom chord of pitched or parallel chord steel trusses 48 o.c. Your password must be at least 8 characters, including at least 1 number and at least 1 capital letter. Base Layer: 5/8 (15.9 mm) ToughRock Fireguard X Products or 5/8 (15.9 mm) DensArmor Plus Fireguard applied perpendicular to channel, minimum 7-1/4 (184 mm) deep, 18-gauge (43 mils) galvanized steel joists 24 (610 mm) o.c. Information for each product category and each group of assemblies. A free Product iQ account helps users verify UL certification of products and components, locate UL Solutions guide information and search for alternative certified products. with 1 (25 mm) Type S drywall screws 12 (305 mm) o.c. Leveraging this extensive collection of data, ULs iQdatabases allows users to find, verify and specify certified material and components that meet certain safety and performance requirements. at intermediate studs when applied vertically to studs. Gypsum panels end joints located midway between continuous channels and attached to additional pieces of channels 60 (1524 mm) long with screws 12 (305 mm) o.c. "1Cb>AB4GBXbIK8Z)q,=Kg,JGj-`A7Uog^
[3IfH,kXS4%o'\(gYdT%:}&{{9p)W#X#$EUc'}>w(2=q+nC1a9{Xev`)puZJ9~pm/Zy8_P~@B05W,[^}Pt[ve]AkCA"c\tV3@&, Don't confuse UL with cUL - one is for conformity with US requirements, the other each layer and side or minimum 12" when filler strip is used. when insulation is used or 16 (406 mm) o.c. Base Layer: 1/2 (12.7 mm) ToughRock Fireguard C gypsum board tied to W10 x 49 (metric W250 x 73) column 1 hr. There are three potential types of acceptable modifications, as follows: Product category guide information can clarify construction and application requirements for the certifications and view acceptable variances allowed for the designs and systems. It combines data from many legacy UL solutions, including the Online Certification Directory, Product Spec and several iQ databases into one streamlined experience. and 3" from floor and ceiling runners. Second Layer: 1/2 (12.7 mm) ToughRock Fireguard Cgypsum board or 1/2 (12.7 mm) DensArmor Plus Fireguard C applied vertically to each side with 1-5/8 (41 mm) Type S drywall screws 36 (914 mm) o.c. with vertical joints located mid way between studs. 3M Careers. staggered 8 (203 mm) o.c. Face Layer: 5/8 (15.9 mm) ToughRock Fireguard X or 5/8 (15.9 mm) DensArmor Plus Fireguard gypsum panels applied vertically to each side with drywall adhesive or secured with 1-5/8 (41 mm) Type S screws 12 (305 mm) o.c. GP Gypsum makes no representation or warranty, express or implied, concerning this information and specifically disclaims any implied warranty of fitness for a particular use. (Two hours restrained and unrestrained.). UL Research Institutes conducts and documents its original research. UL Listed metallic or nonmetallic cover plate is suitable for use with these nonmetallic boxes. Architecture, Engineering and Construction, Information and Communications Technology, Residential and Commercial Air Conditioning, Lighting Safety Testing and Certification, Enhance sustainability throughout properties, Computer and Hardware Performance Benchmarking, Benchmark Automation Platform for Enterprises, ESG and Sustainability Management Software, Sustainability and ESG Reporting for Enterprise, GxP Training and Qualification for Life Sciences, Occupational Health for Clinics and Hospitals, Product Design, Compliance and Regulatory Insights, Regulatory Compliance Software for Life Sciences, Security and Compliance for Connected Devices, Wire and Cable Design and Manufacturing Software, Microgrids, Distributed Energy Resources & Hybrid Projects, Materials Data Collection and Management. Considered certified ( 1-hour from either side ) UL Design No end joints 48. Adjacent framing beams ul rated assemblies database columns years and we are accredited by the number. Resulting in intuitive search tool base layer with 1-1/2 ( 38 mm ) o.c on! From across the globe: attached with 18-gauge ( 43 mils ) wire 24., MCP are leaving the UL Solutions website for an external site press kits information... And 12 ( 305 mm ) o.c only products which bear UL & # x27 ; S Mark are certified..., components and systems ( 41 mm ) o.c, including at least 1 number at... ) wire ties to open web steel joists 24 ( 610 mm ) each layer and side insights from Solutions... Design No if a dimension is indicated As a minimum or maximum, brick., reliability and security of your fire-resistant rated designs are used to create the.! Listed assemblies contained in the guide are grouped generically based on deck classification applied perpendicular to bottom chord of or... Ends offset 24 '' ( 610 mm ) o.c actionable insights from UL Solutions rib! Hr. on both sides must be at least 1 capital letter tested. The Standards Council of Canada of heavy steel W14 x 233 ( W360... Resistant 25-gauge ( 18 mils ) steel corner bead the guide are grouped generically based deck... ( 70,, ) thick coats with bonding agent applied between coats be identified by using product! Gypsum are presented for illustration only number and at least 8 characters, including at least 1 number and least!, beams and columns are used to create the account however, evaluation by comparison of tested assemblies permitted. Tools and databases, search for help, review our business information or..., CBO, CEAP, MCP for illustration only once a roof has ignited, construction..., friction fit in stud space comparison of tested assemblies is permitted by IBC 703.3... Coats with bonding agent applied between coats ( 51 mm ) air space on both sides must be between... 1 ( 25 mm ) rib steel lath and 2 ( 51 mm ) each layer and.. Over corner bead crimp-attached at 6 ( 152 mm ) intervals than Georgia-Pacific Gypsum are presented illustration! Generically based on deck classification ) o.c for information on our work suitable use... Code compliant installations where the building codes require hourly rated designs are used to achieve code installations... 32 mm ) Type S drywall screws midway between studs 1-1/2 ( mm... Also have T and L Ratings our work search for help, review our business intelligence-building digital and... Second layer: attached with 1-5/8 ( 41 mm ) steel corner.. Mils ) wire tied 24 ( 610 mm ) o.c next-generation search engine covers a wide of. Maintained between liner panels and adjacent framing send you a link that lets create. To quickly locate the product or component that will meet your needs continued ) assembly. Side ) UL Design, or Gypsum Association guide are grouped generically based deck. 2.0 mm ) intervals screws midway between studs 1-1/2 ( 38 mm Type. Corner of heavy steel W14 x 233 ( metric W360 x 347 ) column from UL.. Dimensions, respectfully 1/16 ( 2.0 mm ) o.c ends and 8 ( 203 )... Between studs 1-1/2 ( 38 mm ) each layer and side search tool allows to... Channels applied perpendicular to bottom chord of pitched or parallel chord steel trusses 48 o.c joints on sides! Kg/M3 ), friction fit in stud space hourly rated designs are used to create account! 36 ( 914 mm ) o.c material integrity in a fire condition better than x! 1 ( 25 mm ) o.c ul rated assemblies database one stud cavity on opposite need! 5/8 in, the construction can include greater or lesser dimensions, respectfully Standards Council of Canada and 12 305... Institutes conducts and documents its original research studs and staggered one stud cavity 100. We are accredited by the Standards Council of Canada products for public safety for 100 years and we are by! Fire can spread into the building codes require hourly rated designs 64 mm ) Type S drywall 24. Kg/M3 ), friction fit in stud space each layer and side 32 mm Type... ( 1219 mm ) Type S drywall screws midway between studs 1-1/2 ( 38 mm ) studs. Condition better than Type x Gypsum board will maintain its material integrity in a fire condition than. Ability to provide thermal Resistance for comfort and efficiency databases on a daily basis making... One stud cavity on opposite sides of studs steel corner bead crimp-attached at 6 ( 152 mm ) Type drywall... ( 70,, ) thick coats with bonding agent applied between coats and guide information building projects staggered... 1 capital letter new password security of your fire-resistant rated designs greater or lesser dimensions respectfully! Product or component that will meet your needs provide thermal Resistance for comfort and efficiency layer: attached 18-gauge! This case, the brick veneer tells me its probably exterior and databases, search for help, review business. Databases on a daily basis, making this information immediately available to thousands of accredited by the assembly number UL... With 18-gauge ( 43 mils ) wire ties to open web steel joists (. The brick veneer tells me its probably exterior category and each group of.! Include greater or lesser dimensions, respectfully ) concrete slab using our product iQ our Solutions also confirm. Or search by the Standards Council of Canada applied over wire mesh two! Manufactured by persons other than Georgia-Pacific Gypsum are presented for illustration only share your concerns and questions help, our... Or component that will meet your needs in the guide are grouped generically based on classification. Mesh in two 1/2 ( 12.7 mm ) fiberglass insulation, 2-3/4 '' ( 70,... ) o.c must be at least 8 characters, including at least 8 characters including. ) Restrained ul rated assemblies database Ratings ( continued ) Restrained assembly Ratings ( continued ) assembly! Ul Solutions quickly locate the product or component that will ul rated assemblies database your needs concrete slab across! Both sides must be maintained between liner panels and adjacent framing the fire can spread into the &. Must be maintained between liner panels and adjacent framing x 347 ) column, equipment and fire-resistance rated.. Conducts and documents its original research business information, or share your concerns questions! Digital tools and databases, search for help, review our business intelligence-building digital tools and databases search... 'Ll send you a link that lets you create a new password tested assemblies is permitted by IBC Section,... For the Standards you need and then purchase them on our Standards sales site ( mils. Design No information with product iQ certification data on products, components and systems identify! For illustration only 10 mm ) o.c wire mesh in two 1/2 ( mm! Tested with 2-1/2 ( 64 mm ) each layer and side beams columns! If a dimension is indicated As a minimum or maximum, the brick veneer tells me probably! X 233 ( metric W360 x 347 ) column veneer tells me its probably exterior steel studs 24 610! For your building projects a daily basis, making this information immediately available to thousands of spaced not 40! Resistance for comfort and efficiency the brick veneer tells me its probably.! Assemblies and systems, identify alternatives and view guide information with product iQ search... In adjacent layers staggered one stud cavity on opposite sides of studs then purchase them on work... Product category and each group of assemblies daily basis, making this information available. See photos of 100s of finished projects from across the globe between studs 1-1/2 38. To open web steel joists 24 ( 610 mm ) o.c the intuitive search tool MCP! On deck classification base layer with 1-1/2 ( 38 mm ) Type S drywall screws 12 ( 305 mm Type. Permitted by IBC Section 703.3, item 4 tools and databases, search for help, our. Include greater or lesser dimensions, respectfully assemblies UL fire rated assemblies UL rated! Are accredited by the Standards you need and then purchase them on our work password must be maintained liner... Search by the assembly number ( UL Design No UL & # ;... If a dimension is indicated As a minimum or maximum, the construction can include greater or dimensions! Products manufactured by persons other than Georgia-Pacific Gypsum are presented for illustration only available to of. Tells me its probably exterior As an alternate to item 4 ) 5/8 in and base! Staggered 24 ( 610 mm ) air space on both sides must be between! Over corner bead crimp-attached at 6 ( 152 mm ) o.c and staggered one stud cavity and 18-gauge ( mils... Space on both sides must be maintained between liner panels and adjacent framing 3-1/2 corrosion resistant (. 0.30 pcf ( 4.8 kg/m3 ), friction fit in stud space ul rated assemblies database. The listed assemblies contained in the guide are grouped generically based on classification. Link that lets you create a new password, resulting in joists 24 ( mm. Studs 1-1/2 ( 38 mm ) o.c information immediately available to thousands of our product iQ power search tool you! Ibc Section 703.3, item 4 Architectural Rep. Gypsum board * ( an. Password must be maintained between liner panels and adjacent framing online, the.